[Zurück zur
Trefferliste]
 

Three-year analysis of zirconia implants used for single-tooth replacement and three-unit fixed dental prostheses: A prospective multicenter study.

Universitätsklinikum

Autoren:
Balmer M, Spies BC, Vach K, Kohal RJ, Hämmerle CHF, Jung RE
Titel:
Three-year analysis of zirconia implants used for single-tooth replacement and three-unit fixed dental prostheses: A prospective multicenter study.
Kurzzitat:
Balmer M, Spies BC, Vach K, Kohal RJ, Hämmerle CHF, Jung RE: Three-year analysis of zirconia implants used for single-tooth replacement and three-unit fixed dental prostheses: A prospective multicenter study. Clin Oral Implan Res, 2018; 29 (3): 290-299. : http://dx.doi.org/10.1111/clr.13115
Publikationstyp:
Originalarbeiten in wissenschaftlichen Fachzeitschriften
Abstract:
Aim The aim of the present investigation was to evaluate clinically and radiographically the outcome of zirconia oral implants after 3 years in function. Materials and methods In 60 patients in need of either a single‐tooth replacement or a three‐unit fixed dental prosthesis (FDP), a total of 71 one‐piece zirconia implants were placed and immediately restored with temporary fixed prostheses. After a period of at least 2 months in the mandible and at least 4 months in the maxilla, zirconia‐based reconstructions were cemented. The implants were clinically and radiologically examined at implant insertion, prosthetic delivery, at 6 months and then yearly up to 3 years. A linear mixed model was used to analyze statistically the influence of prognostic factors on changes in the marginal bone level. Results Seventy‐one implants (48 in the mandible, 23 in the maxilla) inserted in 60 patients were restored with 49 crowns and 11 FDP. One patient lost his implant after 5 weeks. Five patients with one implant each could not be evaluated after 3 years. Based on 55 patients with a total of 66 implants, the mean survival rate was 98.5% after 3 years in function. A statistically significant mean marginal bone loss (0.70 mm ± 0.72 mm) has been detected from implant insertion to the 3‐year follow‐up. The largest marginal bone loss occurred between implantation and prosthetic delivery (0.67 mm ± 0.56 mm). After delivery, no statistically significant bone level change was observed (0.02 mm ± 0.59 mm). None of the investigated prognostic factors had a significant influence on changes in the marginal bone level. Conclusions After 3 years in function, the investigated one‐piece zirconia implant showed a high survival rate and a low marginal bone loss. The implant system was successful for single‐tooth replacement and three‐unit FDPs. Further investigations with long‐term data are needed to confirm these findings.
ISSN
0905-7161
URL
http://dx.doi.org/10.1111/clr.13115
Kontakt:
Department für Zahn- Mund- und Kieferheilkunde
Klinik für Zahnärztliche Prothetik
Hugstetterstrasse 55
79106 Freiburg

Tel: +49 761-270-49060
Fax: +49 761-270-49250
Email: zmk-proth-sekretariat@uniklinik-freiburg.de
http://www.prothetik.uniklinik-freiburg.de/
Forschungsbericht der Abteilung für das Jahr 2018