[Zurück zur
Trefferliste]
 

Clinical and patient-reported outcomes of zirconia-based implant fixed dental prostheses: Results of a prospective case series 5 years after implant placement.

Universitätsklinikum

Autoren:
Spies BC, Witkowski S, Vach K, Kohal RJ
Titel:
Clinical and patient-reported outcomes of zirconia-based implant fixed dental prostheses: Results of a prospective case series 5 years after implant placement.
Kurzzitat:
Spies BC, Witkowski S, Vach K, Kohal RJ: Clinical and patient-reported outcomes of zirconia-based implant fixed dental prostheses: Results of a prospective case series 5 years after implant placement. Clin Oral Implan Res, 2018; 29: 91-99. : https://doi.org/10.1111/clr.13072
Publikationstyp:
Originalarbeiten in wissenschaftlichen Fachzeitschriften
Abstract:
OBJECTIVE: To evaluate the clinical and patient-reported outcome of all-ceramic zirconia implant supported fixed dental prostheses (FDPs) 5 years after implant installation. MATERIALS AND METHODS: Thirteen patients were treated with two terminally placed one-piece zirconia implants for a three-unit FDP each. The FDPs consisted of a CAD/CAM-fabricated zirconia framework over-pressed with a fluor-apatite veneering ceramic and were adhesively cemented. Survival and success were assessed by applying modified US Public Health Service (USPHS) criteria and preparation of Kaplan-Meier (KM) plots. Alpha and Bravo ratings were accepted for success (among others including small area veneer chippings and occlusal roughness), whereas Charlie ratings allowing for intra-oral correction (e.g., polishing) were accepted for survival. Furthermore, patient-reported outcome measures (PROMs) were analyzed with the help of visual analogue scales (VAS). Wilcoxon matched-pairs signed-rank test (USPHS criteria) and linear mixed models (PROMs) were used to evaluate time effects on response variables. RESULTS: All patients were available 61.8 ± 1.1 months after implant installation (53.6 ± 3.1 months after final prosthesis insertion). FDP survival was 100%. Significant incidence of veneer chipping (p = .0096) and occlusal roughness (p = .0019) was observed. Charlie rated extent of both phenomena resulted in a KM success estimate of 38.5% (95% CI: 14.1%-62.8%; seven FDPs with obvious roughness, three of them with extended veneer chipping). Compared with the pre-treatment assessments (30%-81% of satisfaction), all surveys at prosthetic delivery showed significantly improved VAS scores (66%-93%; p ≤ .038), except for speech (p = .341). Concerning function, esthetics and self-esteem, no decrease in satisfaction could be observed until the end of follow-up (90%-96%; p ≥ .057), whereas perception of sense (92%) and speech (95%) increased over time (p ≤ .030). Occurrence of technical complications did not correlate with patient satisfaction. CONCLUSIONS: Bi-layered FDPs made from zirconia/fluor-apatite highly satisfied patients but showed significant incidence of technical complications. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd. KEYWORDS: CAD-CAM; case series; ceramics; dental implant; fixed dental prosthesis; zirconia
URL
https://doi.org/10.1111/clr.13072
Kontakt:
Institut für Medizinische Biometrie und Statistik

Stefan-Meier-Strasse 26
79104 Freiburg

Tel: 0761 203 6662
Fax: 0761 203 6680
Email: sec@imbi.uni-freiburg.de
http://www.imbi.uni-freiburg.de
Forschungsbericht der Abteilung für das Jahr 2018